Filter Results By:

Products

Applications

Manufacturers

Power Calibration

Verify power measuring instruments accuracy.

See Also: Calibration, Calibrators, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References


Showing results: 226 - 240 of 255 items found.

  • pHTestr® 5 Waterproof Pocket Testers

    OAKTON Instruments

    These pocket-sized testers have a replaceable single-junction sensor which can be easily switched out, allowing you to save money by using the tester body over and over again. A large LCD makes viewing measurements easy and features a three-color backlight indicating operational mode—blue for measurement, green for calibration and red for alarm condition. Additional features include hold function to lock in measurements, self-diagnostic error message, and status icons for measurement stability and low battery voltage. The IP67-rated housing features an easy-to-grip design and floats if accidentally dropped in water when sensor cap is on. Powered by four AAA batteries, the testers can operate up to 400 hours continuously. To conserve power, the unit will auto power-off after 8 minutes of nonuse.

  • FD-11637, 8-Channel Strain/Bridge Input Device for FieldDAQ

    785641-01 - NI

    8-Channel Strain/Bridge Input Device for FieldDAQ - The FD-11637 can measure eight channels and has built-in bridge completion and voltage excitation to support for quarter-, half-, and full-bridge sensors. It also features anti-alias filtering, offset nulling, and shunt calibration to reduce the effect of noise and improve measurement accuracy. The FD-11637 has an ingress protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 grm vibration. The FD-11637 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11637 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11637 is ideal for test cell and outdoor environments.

  • Pressure Calibrators

    AMETEK Sensors, Test & Calibration

    Our pressure calibrators offer a wide variety of features, accuracies, and pressure ranges. Included are intrinsically safe percent of reading calibrators, reference data recorders, wide-range dual sensor calibrators, and calibrators with built in pressure pumps. Many of our calibrators also offer current measurement, voltage measurement, 24 volt loop power supplies, and even complete systems with pressure pumps and calibration software. In many cases, one handheld calibrator can replace multiple instruments, reducing ongoing recalibration and maintenance costs.

  • Flexible Current Sensor Probe

    CTA - Powertek LLC

    The CTA current sensors convert ac current to an isolated 0-5A current with available ranges from 100A to 10,000A. Because the current sensors are flexible split core, installation is possible without shutting down the LV electrical supply, avoiding expensive down-time costs. Typical applications are retrospective energy monitoring in factories, offices buildings, process control data logging systems, where power, energy and current monitoring is important. Typical applications are factories, offices buildings, ac/dc VFD drives, welding, power conversion and power distribution. For all CTA current sensor models, a NIST/NPL (UKAS) traceable calibration certificate and certificate of conformance is supplied. All CTA sensors use UL94V0 or CSA approved materials. The CTA flexible current sensors are suited to permanent or semi permanent installation. The coil sensor is durable, lightweight, flexible and will easily clip-around a power cable. The 5A output from the CTA current sensor connects direct to installed metering, rotary metering or current transducers.

  • Load Pull

    Focus Microwaves

    All Focus tuners use extremely efficient calibration and tuning algorithms and control electronics based on LAN control (iTuner). This is a merger our proven tuner technology with state of the art control electronics to create the latest tuner generation. The on-board micro-processor and tuning firmware form a self-contained and fully calibrated test instrument. The micro-processor inside the tuner accepts ASCII format communication, via an industry standard TCP/IP interface, controls up to nine stepper motors (tuner axes) and executes interpolation and tuning functions for single probe (CCMT) tuners (one probe per frequency range). For tuners with more than one independent probe (MPT) covering the same frequency range to allow for harmonic tuning, external computing power is required, because of the exponentially growing number of combinations of tuner states (slug positions).

  • ORPTestr® 5 Waterproof Pocket Tester

    OAKTON Instruments

    The pocket-sized OPR tester has a replaceable single-junction sensor which can be easily switched out, allowing you to save money by using the tester body over and over again. A large LCD makes viewing measurements easy and features a three-color backlight indicating operational mode—blue for measurement, green for calibration and red for alarm condition. It is ideal for checking dirty water, heavy metals, sulfides, and organic materials. Additional features include hold function to lock in measurements, self-diagnostic error message, and status icons for measurement stability and low battery voltage. The IP67-rated housing features an easy-to-grip design and floats if accidentally dropped in water when sensor cap is on. Powered by four AAA batteries, the testers can operate up to 400 hours continuously. To conserve power, the unit will auto power-off after 8 minutes of nonuse.

  • High Speed Data Logger

    9330 - Interface Inc.

    The Model 9330 displays 24-bit resolution and has an impressive 3750Hz update rate. Incorporating peak and valley capture, it can store up to 6 sensor calibrations and measurements from load cells or torque transducers can be logged at 1000Hz to a standard SD card. This data can then be downloaded to a PC via the built-in USB port and Windows compatible software for off-site analysis. Adding further versatility, the rechargeable battery can power up to 4 x 350 ohm sensors, but also offers up to 300 hours stand by time and up to 20 hours continue use.

  • 3 Wire (Digital) Earth Resistance Tester

    ST-1520 - Standard Electric Works Co., Ltd

    ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Auto power off function.● The timer operates automatically for about three to five minutes when the "PUSH BUTTON SWITCH" and "TIMER ON BUTTON" are pressed together. This will keep test "ON" for the duration of the timer.● Timer for test function (count 3-5 minutes).● Battery operated.● Data hold function.● Small and light weight.● Calibration performed with supplied test leads.

  • MPO Power Meter, MPO Light Source

    JW3224. JW3124 - Shanghai Joinwit optoelectronic Tech,co.,Ltd

    JW3224MPO Optical Power Meter and JW3124MPO Optical Light Source is special for testing MPO fiber. At recent years, as the rapid development of data centre and cloud computing, also with rapid growth of multi fibers” (MPO) requirement. However, on the site of measurement process, traditional single channel Optical power meter with complex measurement and low credibility. Based on this, JW3224&JW3124 MPO products arises at this monment. The product can test the insertion loss of MPO fibers and polarity with only one key, And the integration of a variety of data storage, threshold analysis, data export and other applications,Compared with the traditional instrument, the test efficiency of JW3224 & JW3124 is more than 10 times,it is the best choice for field application of MPO room test、calibration of production line、Determination of polarity.

  • Universal Signal Conditioner

    Model UDA - tecsis LP

    Model UDA is a universal signal conditioner and amplifier designed for use with all full bridge, strain gage-based transducers. Model UDA turns the analog signal into a user-selectable output of ±5Vdc, ±10Vdc, or 4-20mA. This versatile unit features selectable excitation of 2.5 or 5.0Vdc bridge voltage and has a wide DC power input range from 11 to 28Vdc to adapt to a variety of installations. Model UDA includes a wide zero and span adjustment range and a symmetry adjustment for applications requiring precision in both tension and compression. The configurable low pass filter actively removes unwanted high frequency signal components. The unit is housed in a rugged DIN-mountable enclosure with screw terminals to provide connection for power, analog output, shunt calibration, and sensor signals.

  • Active Monopole Antenna

    AM-741 - Com-Power Corporation

    The 41 inch Monopole antenna is required for making electric field emission measurements below 60 MHz per Military standards (MIL-STD-461) and FAA (DO-160) specifications. This antenna is for emissions measurements only. It cannot be used for transmitting. The Active Monopole antenna is generally used in a shielded room or in a screen room, with the equipment under test (EUT) placed on a metal ground plane. The 41 inch rod and the ground plane behave electrically as though a mirror image of the rod were located below the ground, and the ground removed. Since the stainless steel plate does not have enough surface area to mirror the entire 41 inch rod, it is bonded to the surrounding ground plane during use. The AM-741 is battery powered to prevent measurement errors that maybe caused by external power cables. The ANSI equivalent capacitance substitution (ECSM) method is the recommended method for calibrating AM-741 monopole antenna. The individual calibration data will be included with each antenna.

  • Level System

    Universal II - AMETEK Drexelbrook

    The Universal II level transmitter offers increased reliability, low maintenance and an intrinsically safe design for dependable level measurements in all kinds of process liquids, slurries, granulars and interfaces.Universal IIThe Universal II is a two wire level transmitter that eliminates the need for line power in the field and saves costs for additional hardware. It provides reliable level measurements in all kinds of process liquids, slurries, granulars and interfaces.When powered from an approved source this level transmitter can be made intrinsically safe. Its rugged contruction resists corrosion and abraision. The no moving parts design eliminates break downs.The Universal II level transmitter utilizes RF Admittance technology with manual calibration and a 4 – 20 mA output signal. The patented Cote-Shield circuitry ensures accuracy and reliability regardless of product build-up on the level transmitter.This level system is unaffected by changes in the process material density, pressure, or temperature variations.

  • RF Signal Generators

    Transcom Instruments

    The G6 VSG from Transcom Instruments is a Vector Signal Generator that operates from 10 MHz to 6 GHz. It can simulate GSM, EDGE, CDMA, TD-SCDMA, WCDMA, CDMA2000, TD-LTE, FDD-LTE, NB-IoT, and LoRa base station signals for production and calibration of UE, chips. The signal generator has a dynamic range (power range) from -100 to 10 dBm and an in-built automatic gain control function. It is available in a module that measures 180 x 50 x 290 mm and is ideal for educational practices, wireless monitoring, mobile communication, aerospace and national defense industry in terms of research, manufacturing, testing and measurement, and electronic countermeasure.

  • Portable Digital Manometer

    PS309 - Validyne Engineering

    Featured are an integral variable reluctance transducer, solid state electronics module, 3 digit liquid crystal display (LCD)* and battery pack with six 1.5V penlight cells for truly portable operation. The units can also be powered from an external DC power supply or AC battery eliminator (converter) module. The transducer features all corrosion resistant materials in contact with the pressure media (both ports in differential units), very low internal cavity volumes and ultra-low volumetric displacement with full-scale pressure excursion. Transducer calibration is unaffected by dielectric properties of the sensed fluid. Gauge and differential transducers may be disassembled and range changed by simple diaphragm replacement.

  • RF Conducted Immunity Test System

    RFCI61000-4-6 - Lisun Electronics Inc.

    RFCI61000-4-6 RF Conducted Immunity Test System is an automatic test system which is for the conduction sensitivity testing, it is fully meets IEC61000-4-6.2006, ISO11452-4, GB/T17626.6-2008 and GTB152B-CS114 etc standards. RFCI61000-4-6 internal source and broadband power amplifier can be generated 3 voltage test levels: 1v, 3v and 10v, and has the function of the real detect output level. It has two operation software which is calibration software and test software. When measuring, the signal is in 1 KHZ sine wave amplitude modulation system (80%) to simulate the actual harassment, and can through the coupling/decoupling network (CDN or electromagnetic clamp) to make the harassment signal coupled to the device.

Get Help